K-Prema Internal Seal

Internal Pipe Seal for man-entry pipelines

The K-Prema Internal Pipe Seal System is a mechanical point repair system designed for the rehabilitation and repair of localised damage within man-entry pipelines.

Manufactured to suit a range of sewage water, oil and air applications, the K-Prema range can be utilised on an array of pipe materials including concrete, steel, cast iron, PE, glassfibre and other materials. Available for pipelines from 500mm to 4000mm, K-Prema is manufactured from a WRAS-approved material and will withstand an internal pressure of 20 bar.

High-quality manufacturing and durable under pressure.

The system consists of an EPDM rubber sleeve and clamping bands made of high grade 304 stainless steel.

K-Prema has a maximum internal pressure rating of 20 bar (290psi) and an external pressure range of between 0.5-1 bar. Additional clamp bands can be installed across the width of the coupling to resist higher external pressures.

The system is easy to use, with a simple installation process, the tools required arespecial hydraulic ram and hand pump (These can be purchased or hired from S1E. Call 01226 397015 or email contact@s1e.co.uk.)

The K-Prema system also includes a range of liner end seals which can be easily removed in case of improper installation, damage or failure and provides protection to the edge of the liner.

Provides a durable and watertight seal with high elasticity to maintain contact.

K-Prema is an efficient method of sealing pipes that are damaged due to corrosion, displaced joints, tree roots and ground movement.

  • Manufactured from a WRAS-Approved material.
  • Simple and fast assembly using an uncomplicated mechanical mounting technique, taking from as little as 30 minutes.
  • No excavation required, only one entrance to the pipeline is required.
  • Cost effective solution, and can be used to repair a variety of pipe materials including; concrete, steel, cast iron and plastics.
  • High maximum Internal pressure rating of 20 bar (290psi)
  • Possible dismantling and complete reusability – ecologically harmless.
  • Internal pipe seal range:500mm to 4,000mm pipes.
  • Seal bands are available at 280mm, 330mm and 480mm widths, to suit various applications.

Our Customers Say...

"We had a problem with some 600mm twin wall plastic pipe. Excavating and relaying would have been an expensive solution. After speaking to a colleague who had previously used your product, we placed an order and after 1 day all 5 seals had been installed and air tested – we will definitely use this product again."

Darren Mullins, Wessex Water

K-Prema Installation:Watertight rehabilitation for larger pipes.

Ensure any Confined Space legislation or regulations are complied with.

  1. Lay the seal in the bottom of the pipe and position symmetrically across the point of repair. Place retaining bands in the rubber location grooves in the bottom half of the coupling.
  2. At each end of these retaining bands position a stainless steel shim between the rubber and the stainless band, with half the length projecting beyond the end of the band. These shims are to prevent the ends of the retaining bands pressing into the rubber and should be used.
  3. Locate the top halves of the retaining bands into the grooves in the rubber seal on top of the bottom bands. This will hold the hoops in position prior to expansion of the joints.
  4. Position the hydraulic ram between the lugs that are welded onto the ends of the retaining bands. The hydraulic ram is then lightly pressurized to force the two ends apart.
  5. A spacer wedge of a suitable dimension should be placed in the gap created by this expansion. The pressure is released and the ram taken out. This should be repeated at all the junctions in the retaining bands.
  6. Each junction should now be re-tensioned with increased ram pressure. Ensure any friction between the rubber and the retaining band is overcome and that the band seats fully against the seal, by tapping with a hammer.
  7. Repeat this process until all junctions have maximum sized spacers fitted and the seal is fully located.

Note:The area around the pipe joint needs to be clean and free of any dirt and loose debris and all the voids should be filled. With concrete pipes, surface preparation would be advisable. After install, return and re-check seal 24 hours after installation and re-expand if required due to relaxation of the rubber.

S1E supply the K-Prema Internal Pipe Seal System

Contact the S1E Sales Team for more information and orders by calling 01226 397 015, or emailing sales@s1e.co.uk.

 

Alternatively send your enquiry via the contact form below.

 

enquiry form for K-Prema seals.

Cookie Preferences

By selecting the below you are agreeing to our cookie policy

Select the options you would like to use


Essential Cookies

We use cookies to provide and improve our services. By continuing to browse or by clicking 'Accept', you agree to the storing of cookies on your device to enhance your site experience and for analytical purposes.

Google Analytics tracking